“Passive fire protection (PFP) coatings make structures more resistant to fire by insulating structural steel from high temperatures and as a result, buy time for the evacuation before structural collapse.
The Graco XM™ PFP Plural-Component Sprayer offers data reporting technology, so you can confirm that epoxy intumescent coatings are sprayed on-ratio, at requirements set by the manufacturer. The XM PFP is easy to use, maintains consistent temperature control and offers precise ratio control.”
Count on Graco XM PFP for accurate, on-ratio mixing
Handles two-part epoxy intumescent fire protection coatings from 1:1 to 10:1
Provides precise ratio control
If off-ratio conditions occur, the system will automatically stop
Offers data reporting for verification the material was properly applied
Monitors, tracks and collects data for: mix ratio, pressure, temperature, flow rates and material usage
USB port to easily download data reports
Accurate, on-ratio mixing reduces material waste
Virtually eliminates the difficult task of removing improperly mixed material
Offers peace of mind with "set and forget" parameter settings
Model | XM PFP |
---|---|
Mix Ratio Range | 1:1-10:1 (in 0.01 increments) |
Ratio Tolerance Range (before alarm) | +/- 5% |
Maximum Flow Rate (measured with oil) | 13.6 liters per minute |
Fluid Viscosity Range | 31.75 mm ID |
Fluid Viscosity Range | Handles mastic materials which are loaded into heated tankswith ram-fed priming piston pumps |
Fluid Inlets | Pail (Feed Pumps) |
Maximum Fluid Working Pressure for A and B Materials | 41 MPa, 414 bar |
Maximum Fluid Working Pressure for Heating | 0.7 MPa, 7 bar |
Maximum Fluid Temperature | 70°C |
Minimum Air Consumption | 2.8 meter³/min |
Maximum Air Consumption | 7.1 meter³/min |
Voltage (can be set with jumpers) | Option 1: 220-240V, 3 phase DELTA (3 wire plus ground) Option 2: 380-400V, 3 phase WYE (4 wire including neutral plus ground) |
Wattage | 18,400 watts (23,400 with optional flush water heater) |
Amps | 240V, 3-phase models: 65 Amps per phase full load: 380V, 3-phase models: 38 Amps per phase full load |
Machine | CE, ETL |
Pressure Tanks | ASME, CE |