Passive fire protection (PFP) coatings strengthen structures against fire by insulating structural steel from high temperatures, allowing more time for evacuation before structural collapse. Passive fire protection equipment like Intumescent Fireproofing Sprayers plays a crucial role in ensuring effective fire resistance. The Graco XM™ PFP Plural-Component Sprayer provides data reporting technology, so you can confirm that epoxy intumescent coatings are sprayed on-ratio according to the manufacturer’s requirements. The XM PFP ensures ease of use, maintains consistent temperature control, and offers precise ratio control. AEMCO have the experts to train and maintain the XM PFP equipment.
GRACO XM PFP can spray
Jotun Jotachar 1709
Jotun Jotachar JF750
Jotun Jotachar JF750 XT
Akzo Nobel Chartek 2218
Akzo Nobel Chartek 1709
Akzo Nobel Chartek 7
Akzo Nobel Chartek 1
PPG Pitt-Char NX
Hempel Hemafire XTR100
Carboline Thermolag 3000
Count on Graco XM PFP for accurate, on-ratio mixing
Handles two-part epoxy intumescent fire protection coatings from 1:1 to 10:1
Provides precise ratio control
If off-ratio conditions occur, the system will automatically stop
Offers data reporting for verification the material was properly applied
Monitors, tracks and collects data for: mix ratio, pressure, temperature, flow rates and material usage
USB port to easily download data reports
Accurate, on-ratio mixing reduces material waste
Virtually eliminates the difficult task of removing improperly mixed material
Offers peace of mind with "set and forget" parameter settings
| Model | XM PFP |
|---|---|
| Mix Ratio Range | 1:1-10:1 (in 0.01 increments) |
| Ratio Tolerance Range (before alarm) | +/- 5% |
| Maximum Flow Rate (measured with oil) | 13.6 liters per minute |
| Fluid Viscosity Range | 31.75 mm ID |
| Fluid Viscosity Range | Handles mastic materials which are loaded into heated tankswith ram-fed priming piston pumps |
| Fluid Inlets | Pail (Feed Pumps) |
| Maximum Fluid Working Pressure for A and B Materials | 41 MPa, 414 bar |
| Maximum Fluid Working Pressure for Heating | 0.7 MPa, 7 bar |
| Maximum Fluid Temperature | 70°C |
| Minimum Air Consumption | 2.8 meter³/min |
| Maximum Air Consumption | 7.1 meter³/min |
| Voltage (can be set with jumpers) | Option 1: 220-240V, 3 phase DELTA (3 wire plus ground) Option 2: 380-400V, 3 phase WYE (4 wire including neutral plus ground) |
| Wattage | 18,400 watts (23,400 with optional flush water heater) |
| Amps | 240V, 3-phase models: 65 Amps per phase full load: 380V, 3-phase models: 38 Amps per phase full load |
| Machine | CE, ETL |
| Pressure Tanks | ASME, CE |